The Grant-bio CH3-150 Combitherm-2 dry block heating cooling system is specially designed to thermostabilise materials at temperatures from –3°C to +150°C according to methods of analysis.
- Stability: ±0.1ºC
- Independently regulated heating and cooling blocks in the same unit
- Digital timer with sound alarm: 1 min to 99 h 59 min (increment 1 min)
- User adjustable programmes (temperature and time): 16 (heating) + 16 (cooling)
- Digital temperature control for optimum precision
- Temperature Calibration Function
- Protective lid
The CH3-150 has seven interchangeable blocks available. Custom blocks available on request.
Applications
Life-science - storing restriction enzymes, nick translation, ligation reactions, restriction digests, protein solubilisation for PAGE, warm incubation of microcentrifuge tubes for hybridisation, enzyme reactions and deactivations
Clinical - cooling blood samples prior to coagulation testing. acylcarnitines derivatisation, MRSA and PBP2 latex testing, heating flush/media used in egg recovery, fertility to keep test tubes at correct temperature during egg collection
Incubating samples at set temperatures, heating block for boiling of solutions in tubes
Life-science-cell digestion, DNA/RNA extraction, post sequencing PCT clean-up-dry down step, boiling in vitro DNA RNA/ protein samples, incubating invitro reactions/digestions, extraction of DNA for real-time PCR analysis, denaturing nucleic acid and protein samples
Industrial - digestion of environmental samples for chemical oxygen demand analysis, soil digests, maintaining temperatures
Specifications
Dimensions (h x d x w) | 220 x 285 x 295mm |
Heating block temperature range | +25 to +150°C |
Heating block temperature control range | Ambient +5 to +150°C |
Heating block setting resolution | 1°C |
Heating block stability | ±0.1°C |
Cooling block temperature range | –3 to +20°C |
Cooling block temperature control range | Ambient -23 to ambient -5°C |
Cooling block setting resolution | 0.1°C |
Cooling block stability | ±0.1°C |
Digital timer with sound alarm | 1 min–99 hrs 59 min (increment 1 min) |
User adjustable programs (temperature and time) | 16 (heating) + 16 (cooling) |
Display | LCD |
Nominal operating voltage | 230V only (50/60Hz) |
Weight | 5.6kg |
Accessories
Combitherm Dry Block – Options and Accessories
Part No | Description |
B2-50 | Interchangeable block for 2 x Ø 48mm tubes, depth 58mm |
B10-13 | Interchangeable block for 10 x Ø 13mm tubes, flat bottom, depth 30mm |
B10-16 | Interchangeable block for 10 x Ø 16mm tubes, depth 56mm |
B5-29 | Interchangeable block for 5 x Ø 29mm tubes, flat bottom, depth 40mm |
B6-25 | Interchangeable block for 6 x Ø 25mm tubes, depth 40mm |
B18-12 | Interchangeable block for 18 x Ø 12mm tubes, round bottom, depth 58mm |
B23-1.5 | Interchangeable block for 23 x 1.5ml micro tubes |
External Temperature Probes
Part No | Description |
QBEP | Standard probe for in-sample or in-block temperature control; encased in stainless steel sheath, ø3mm x 30mm long, with 350mm of cable. |
QBEP-WM | Short-form probe for in-sample or in-block temperature control; encased in stainless steel sheath, ø3mm x 14mm long, with 350mm of cable. |